Mahsulotlarning xususiyatlari
SZ11 seriyali 33KV klassi Yukdagi kuchlanishni tartibga solish - transformator kuchlanishni o'zgartirishi mumkin bo'lgan kuchlanishni tartibga solish usuli
yuk ostida ishlaganda kran uzatmasini o'zgartirish orqali.Quvvat elektron komponentlari kalitlari tez-tez almashtirishning afzalliklariga ega,
uchqun yo'q va uzoq xizmat muddati, shuning uchun ular tarqatish transformatorlari uchun yuk ostida krani almashtirgich sifatida ishlatilishi mumkin.
Standard
GB1094.1-2013;GB1094.2-2013;GB1094.3-2013;GB1094.5-2008;GB/T 6451-2008;GB/T1094.10-2003;JB/T10088-2004
IEC60076;SANS 780 STANDARTLARI
Mahsulotlarning xususiyatlari
1. ANSIga mos keladi yoki undan oshadi.IEC.GB.SANS.Standartlar
2. Xavfsiz ishlov berish, o'rnatish va ishlatish.
3. Jozibali, zamonaviy ko'rinish
4. Oqilona tuzilma
5. To'liq muhrlangan
6. Tizimning yuqori ishonchliligi
7. Ishlashda yuqori xavfsizlik va ishonchlilik
8. Haddan tashqari yuk va samaradorlikning yuqori quvvati
9. Qisqa tutashuv va issiqlikka chidamlilik qobiliyatiga ega mustahkam qurilish
10. EVERPOWER transformatorlari yuksiz yo‘qotishlarni kamaytirish va yuk yo‘qotishlarni kamaytirish tufayli yanada samaraliroq.
Transformatorning normal xizmat ko'rsatish shartlari
1.Dengiz sathidan balandligi 1000m dan past;
2.Atrof-muhit harorati;
3. Eng yuqori havo harorati + 40 ℃;
4.Eng yuqori kunlik o'rtacha havo harorati +30 ℃;
5. Eng yuqori yillik o'rtacha havo harorati + 20 ℃;
6. Eng past tashqi havo harorati - 25 ℃;
SZ11 seriyali 33 kV yuk ostida tartibga soluvchi quvvat transformatorining texnik ma'lumotlari | |||||||||||||
Baholangan Imkoniyat (kVA) | Voltaj guruhi (kV) | Vektor Guruh | Empedans kuchlanishi | Yo'qotish (kVt) | Yuksiz joriy | Og'irligi (kg) | Kontur o'lchami | Vertikal o'lchagich gorizontal (mm) | |||||
Yuqori Kuchlanishi | Past Kuchlanishi | % | Yuksiz | Yuklash | % | Mashina vazn | Yog ' vazn | Yalpi vazn | |||||
Yd11 | 6.5 | 1.30 | 10.40 | 1.00 | 1350,0 | 700 | 2780 | 2790*1220*2150 | 820/820 | ||||
1000 | 1.52 | 12.80 | 1.00 | 1575,0 | 775 | 3290 | 2830*1240*2250 | 820/820 | |||||
1250 | 1.86 | 15.40 | 0,90 | 1810.0 | 880 | 3845 | 2870*1310*2370 | 820/820 | |||||
1600 | 2.24 | 18.43 | 0,80 | 2190.0 | 4295 | 2900*1510*2420 | 820/820 | ||||||
2000 | 2.88 | 20.25 | 0,70 | 2460.0 | 1090 | 4890 | 2920*1750*2450 | 820/820 | |||||
2500 | 38.5 | 3.40 | 21.73 | 0,60 | 3010.0 | 1205 | 5660 | 2980*1840*2530 | 1070/1070 | ||||
3150 | 36 | 11 | 7 | 4.04 | 26.01 | 0,56 | 3785.0 | 1500 | 7600 | 3150*2220*2620 | 1070/1070 | ||
4000 | 35 | 10 | 4.84 | 30.69 | 0,56 | 4690.0 | 8500 | 3270*2390*2670 | 1070/1070 | ||||
5000 | 34.5 | 6 | 5.80 | 36.00 | 0,48 | 5570.0 | 2015 yil | 9790 | 3470*2580*2950 | 1070/1070 | |||
6300 | 33 | 7.5 | 7.04 | 38.70 | 0,48 | 7380.0 | 2460 | 12620 | 3700*2580*2950 | 1475/1475 | |||
8000 | Ynd11 | 9.84 | 42,75 | 0,42 | 8870.0 | 2650 | 14100 | 3850*2680*3150 | 1475/1475 | ||||
10000 | 11.60 | 50,58 | 0,42 | 10020.0 | 2930 | 16500 | 3920*3720*3230 | 1475/1475 | |||||
12500 | 8 | 13.66 | 59,85 | 0,40 | 12880.0 | 3710 | 19780 | 4010*2950*3410 | 1475/1475 | ||||
16000 | 16.46 | 74.02 | 0,40 | 16120.0 | 4280 | 23950 | 4120*3180*3570 | 1475/1475 | |||||
20000 | 19.46 | 87.14 | 0,40 | 18580.0 | 5230 | 29600 | 4330*3560*3990 | 1475/1475 |
Eslatma: U kuchlanishni ± 3 × 2,5% yoki ± 2 × 2,5% yuqori kuchlanishli yuk regulyatori uchun tartibga solish diapazoni bilan ta'minlashi mumkin.
UCH FAZALI MOG BOTIRIB AMORF
Qotishmalarni taqsimlash transformatorining texnik ma'lumotlari
Baholangan Imkoniyat (kVA) | Voltaj birikmasi (kV) | Vektor guruhi | Yuksiz Yo'qotish (kV) | Yukni yo'qotish (KVt) | Yuksiz joriy % | Empedans kuchlanishi % | ||
Yuqori Kuchlanishi | HV krani almashtirgich (%) | LV(kV) | ||||||
30 | 0,33 | 0,60 | 1.70 | 4.0 | ||||
50 | 0,43 | 0,87 | 1.30 | |||||
63 | 0,50 | 1.04 | 1.20 | |||||
80 | 0,60 | 1.25 | 1.10 | |||||
100 | 0,75 | 1.50 | 1.00 | |||||
125 | 0,85 | 1.80 | 0,90 | |||||
160 | 0,10 | 2.20 | 0,70 | |||||
200 | 13.8 | 0,12 | 2.60 | 0,70 | ||||
250 | 13.2 | ±5 | 0.4 | 0,14 | 3.05 | 0,40 | ||
315 | 11 | ±2*2,5 | 0,415 | Dyn11 | 0,17 | 3.65 | 0,50 | |
400 | 10.5 | 0,433 | Dyn5 | 0,20 | 4.30 | 0,50 | ||
500 | 10 | 0,24 | 5.15 | 0,50 | ||||
630 | 6 | 0,32 | 6.20 | 0,30 | 4.5 | |||
10 | 0,38 | 7.50 | 0,30 | |||||
1000 | 6 | 0,45 | 10.30 | 0,30 | ||||
1250 | 0,53 | 12.00 | 0,20 | |||||
1600 | 0,63 | 14.50 | 0,20 | |||||
2000 | 0,75 | 17.40 | 0,20 | 5.0 | ||||
2500 | 0,90 | 20.20 | 0,20 |
Eslatma: Yuqori kuchlanishli yukni regulyator transformatori uchun ± 4 × 2,5% kuchlanishni tartibga solish diapazoni bilan ta'minlashi mumkin